MINNESOTA MINING AND MFG CO -- 3505O GLASS IONOMER LUTING CEMENT POWDER -- 6520-01-419-5037
===================== Product Identification ===================== Product ID:3505O GLASS IONOMER LUTING CEMENT POWDER MSDS Date:08/13/1996 FSC:6520 NIIN:01-419-5037 === Responsible Party === Company Name:MINNESOTA MINING AND MFG CO Address:3M CTR City:SAINT PAUL (FORMALLY IN DETROITT, MI) State:MN ZIP:55144-1000 Country:US Info Phone Num:612-733-1341/612-733-1110 Emergency Phone Num:612-733-1341 CAGE:76381 === Contractor Identification === Company Name:MINNESOTA MINING AND MFG CO, DBA 3M Address:3M CENTER BLDG 224-5S-04 Box:City:SAINT PAUL State:MN ZIP:55144-1000 Country:US Phone:866-556 5712 / 612-733-1110 CAGE:76381 ============= Composition/Information on Ingredients ============= Ingred Name:GLASS CAS:66599-17-3 Fraction by Wt: 93-97% Other REC Limits:NONE RECOMMENDED Ingred Name:METHACRYLIC ACID, 3-(TRIMETHOXYSILYL)PROPYL ESTER CAS:2530-85-0 RTECS #:UC0230000 Fraction by Wt: 1-5% Other REC Limits:NONE RECOMMENDED OSHA PEL:NOT ESTABLISHED. ACGIH TLV:NOT ESTABLISHED. Ingred Name:TITANIUM DIOXIDE CAS:13463-67-7 RTECS #:XR2275000 Fraction by Wt: <1.0% Other REC Limits:NONE RECOMMENDED OSHA PEL:15 MG/M3 TDUST ACGIH TLV:10 MG/M3 TDUST; 9596 ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:EYE:MECHANICAL EYE IRRIT:IRRIT,REDNESS,SCRATCHING OF CORNEA AND TEARING.SKIN:MECHANICAL SKIN IRRIT:ITCHING,REDNESS.INHA:IRRIT(UPPER RESP):SORENESS OF NOSE/THROAT,COUGHING,SNEEZING.LUNG DMG:COUGHING,DI FFICULTY BREATHING,WHEEZING,TIGHTNESS INCHEST,CONGESTION,COUGHING UP OF BLOOD.INGEST:NO ADVERSE HEALTH EFFECTS EXPECTED. Effects of Overexposure:EYE:IRRIT,REDNESS,SCRATCHING OF CORNEA,TEARING. SKIN:IRRIT,ITCHING,REDNESS. INHAL:UPPER RESP IRRIT,SORENESS OF NOSE/THROAT,COUGHING,SNEEZING,LUNG DMG-COUGHING,DIFFICULTY BREATHING,WHEEZING,TIGHTNESS I N CHEST,CONGESTION,COUGHING UP BLOOD. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:EYE:IMMED FLUSH W/LG AMTS OF WATER.GET IMMED MED ATTN.SKIN:WASH AFFECTED AREA W/SOAP/WATER.INHAL:IF SIGNS/SYMPTOMS OCCUR REMOVE PERSON TO FRESH AIR.IF SIGNS/SYMPTOMS CONTINUE CALL PHYSICIAN.INGEST:NO NEEDE FOR FIRST AID IS ANTICIPATED. ===================== Fire Fighting Measures ===================== Flash Point:NA Autoignition Temp:Autoignition Temp Text:NA Lower Limits:NA Upper Limits:NA Extinguishing Media:NON-COMBUSTIBLE.CHOOSE MATERIAL SUITABLE FOR SURROUNDING FIRE. ================== Accidental Release Measures ================== Spill Release Procedures:OBSERVE PRECAUTIONS FROM OTHER SECTIONS.COLLECT SPILLED MATL.USE WET SWEEPING COMPOUND OR WATER TO AVOID DUSTING.CLEAN UP RESIDUE.PLACE IN US DOT-APPROVED CONTAINER. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN COOL PLACE.STORE AWAY FROM HEAT.KEEP CONTAINER DRY. Other Precautions:NONE SPECIFIED BY MANUFACTURER. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:AVOID BREATHING OF AIRBORNE MATL.SELECT ONE OF FOLLOWING NIOSH APPROV RESP BASED ON AIRBORNE CONCENTRATION OF CONTAMINANTS AND IAW OSHA REGS:HALF-MASK DUST RESPIRATOR,FULL-FACE DUST RESPIRATOR. Ventilation:USE IN WELL-VENTILATED AREA. Protective Gloves:AVOID PROL/REP SKIN CONTACT Eye Protection:AVOID EYE CONTACT Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER. Work Hygienic Practices:DO NOT INGEST. Supplemental Safety and Health ================== Physical/Chemical Properties ================== HCC:N1 Boiling Pt:B.P. Text:NA Melt/Freeze Pt:M.P/F.P Text:NA Decomp Temp:Decomp Text:NP Vapor Pres:NA Vapor Density:NA Spec Gravity:2.8GM/ML pH:NA Viscosity:NA Evaporation Rate & Reference:NA Solubility in Water:NA Appearance and Odor:COARSE POWDER (GREATER THAN 10UM IN DIAMETER),WHITE POWEDER, ODORLESS Percent Volatiles by Volume:NP Corrosion Rate:NP ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES ==================== Disposal Considerations ==================== Waste Disposal Methods:INCINERATE IN INDUSTRIAL OR COMMERCIAL FACILITY.SEND TO 3M CHEMOLITE PLANT,BLD 47 OR TO 3M-APPROVED CHEMICAL WASTE DISPO FACILITY.SINCE REGS VARY,CONSULT APPLICABLE REGS OR AUTHORITIES BEF DISPO.US EP A HAZ WASTE#=NONE. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.